Skip to content Skip to navigation

Connexions

You are here: Home » Content » Linear Phase Filters

Navigation

Content Actions

  • Download module PDF
  • Add to ...
    Add the module to:
    • My Favorites
    • A lens
    • An external social bookmarking service
    • My Favorites (What is 'My Favorites'?)
      'My Favorites' is a special kind of lens which you can use to bookmark modules and collections directly in Connexions. 'My Favorites' can only be seen by you, and collections saved in 'My Favorites' can remember the last module you were on. You need a Connexions account to use 'My Favorites'.
    • A lens (What is a lens?)

      Definition of a lens

      Lenses

      A lens is a custom view of Connexions content. You can think of it as a fancy kind of list that will let you see Connexions through the eyes of organizations and people you trust.

      What is in a lens?

      Lens makers point to Connexions materials (modules and collections), creating a guide that includes their own comments and descriptive tags about the content.

      Who can create a lens?

      Any individual Connexions member, a community, or a respected organization.

    • External bookmarks
  • E-mail the author

Recently Viewed

Linear Phase Filters

Module by: Douglas L. Jones

In general, for -πωπ ω Hω=|Hω|-θω H ω H ω θ ω Strictly speaking, we say Hω H ω is linear phase if Hω=|Hω|-ωK- θ 0 H ω H ω ω K θ 0 Why is this important? A linear phase response gives the same time delay for ALL frequencies! (Remember the shift theorem.) This is very desirable in many applications, particularly when the appearance of the time-domain waveform is of interest, such as in an oscilloscope. (see Figure 1)

Figure 1
imag001.png

Restrictions on h(n) to get linear phase

Hω=h=0M-1hn-ωn=h0+h1-ω+h2-2ω++hM-1-ωM-1=-ωM-12h0ωM-12++hM-1-ωM-12=-ωM-12h0+hM-1cosM-12ω+h1+hM-2cosM-32ω++h0-hM-1sinM-12ω+ H ω h 0 M 1 h n ω n h 0 h 1 ω h 2 2 ω h M 1 ω M 1 ω M 1 2 h 0 ω M 1 2 h M 1 ω M 1 2 ω M 1 2 h 0 h M 1 M 1 2 ω h 1 h M 2 M 3 2 ω h 0 h M 1 M 1 2 ω (1)
For linear phase, we require the right side of Equation 1 to be - θ 0 (real,positive function of ω) θ 0 (real,positive function of ω) . For θ 0 =0 θ 0 0 , we thus require h0+hM-1=real number h 0 h M 1 real number h0-hM-1=pure imaginary number h 0 h M 1 pure imaginary number h1+hM-2=pure real number h 1 h M 2 pure real number h1-hM-2=pure imaginary number h 1 h M 2 pure imaginary number Thus hk= h * M-1-k h k h * M 1 k is a necessary condition for the right side of Equation 1 to be real valued, for θ 0 =0 θ 0 0 .

For θ 0 =π2 θ 0 2 , or - θ 0 =- θ 0 , we require h0+hM-1=pure imaginary h 0 h M 1 pure imaginary h0-hM-1=pure real number h 0 h M 1 pure real number hk=- h * M-1-k h k h * M 1 k

Usually, one is interested in filters with real-valued coefficients, or see Figure 2 and Figure 3.

Figure 2: θ 0 =0 θ 0 0 (Symmetric Filters). hk=hM-1-k hk h M1 k.
imag002.png
Figure 3: θ 0 =π2 θ 0 2 (Anti-Symmetric Filters). hk=-hM-1-k hk h M1 k.
imag003.png
Filter design techniques are usually slightly different for each of these four different filter types. We will study the most common case, symmetric-odd length, in detail, and often leave the others for homework or tests or for when one encounters them in practice. Even-symmetric filters are often used; the anti-symmetric filters are rarely used in practice, except for special classes of filters, like differentiators or Hilbert transformers, in which the desired response is anti-symmetric.

So far, we have satisfied the condition that Hω=Aω- θ 0 -ωM-12 H ω A ω θ 0 ω M 1 2 where Aω A ω is real-valued. However, we have not assured that Aω A ω is non-negative. In general, this makes the design techniques much more difficult, so most FIR filter design methods actually design filters with Generalized Linear Phase: Hω=Aω-ωM-12 H ω A ω ω M 1 2 , where Aω A ω is real-valued, but possible negative. Aω A ω is called the amplitude of the frequency response.

excuse:

Aω A ω usually goes negative only in the stopband, and the stopband phase response is generally unimportant.

note:

|Hω|=±Aω=Aω-π121-signAω H ω ± A ω A ω 1 2 1 sign A ω where signx=1ifx>0-1ifx<0 sign x 1 x 0 -1 x 0

Example 1

Lowpass Filter

Figure 4
Desired |H(ω)|
imag004.png
Figure 5: The slope of each line is -M-12 M1 2.
Desired ∠H(ω)
imag005.png
Figure 6: AωAω goes negative.
Actual |H(ω)|
imag006.png
Figure 7: 2π 2 phase jumps due to periodicity of phase. π phase jumps due to sign change in Aω A ω .
Actual ∠H(ω)
imag007.png
Time-delay introduces generalized linear phase.
note:
For odd-length FIR filters, a linear-phase design procedure is equivalent to a zero-phase design procedure followed by an M-12 M 1 2 -sample delay of the impulse response. For even-length filters, the delay is non-integer, and the linear phase must be incorporated directly in the desired response!

Comments, questions, feedback, criticisms?

Send feedback